Input Range: 180Vac-285Vac Input Frequency: 50Hz/60Hz Output: 100V-110V-115V-120V (Selectable) Output Frequency: 50Hz/60Hz (Selectable)
Product Code: EX-16 Product ID: 33173
Product sold by: samstores.com
Availability: In Stock New
Overview
This series is a double conversion Power Converter which produces stable pure sine wave voltage and frequency output (O/P). With the Converter, you can protect your equipment from most of the power problems, including power sags, power surges, and line noise, etc. With the common neutral topology, the Converter provides internal connection from AC I/P neutral to AC O/P neutral; thus, it does not need to use an isolation transformer to provide 0 volt from AC I/P neutral to O/P neutral. This feature will reduce the interference to loads of communication or video system.
Features
With outstanding performance & reliability, the unique benefits of the Converter include the following:
SPECIFICATIONS
STEP-DOWN Voltage and Frequency Converter (EX Series)
Model12060EX-812060EX-1212060EX-1612060EX-21
Output
Capacity1000VA/900W1500VA/1350W2000VA/1800W2600VA/2340W
Output Voltage100V/110V/115V/120V Selectable
Output
Current-Amps @ 60Hz8.4 Amp12.6 Amp16.8 Amp21.8 Amp
OUTPUT PEAK CURRENT (<250mS)26 Amp38 Amp50 Amp60 Amp
Voltage Regulation±2% of selected output voltage
Output Frequency
(sync to mains)50±0.05Hz or 60±0.06Hz (Auto-Synchronized to Mains)
Output Frequency
(not sync to mains)50/60Hz (selectable from LCD function button) 50±0.01Hz or 60±0.01Hz
Crest Factor3:1
Voltage WaveformSine Wave
Output Distortion (Resistive Load)<2%
Output Distortion (Reactive Load)<3%
Non-Linear Peak Current for 30 sec.18A27A36A42A
Standby Power18W27W
Total Harmonic Distortion<3% (at full resistive load)
Output EMI FilterN/A
Output RFI Filter30Mhz - 1000Mhz
Clamp Level200V PEAK
Protection
Over load Protection100%~129% for 60 seconds delay, then alarm ; alarm for 60 seconds, then shutdown o/p;
> 130%, alarm for 2 seconds, then shutdown o/p;
4AOutput protected from short circuit by pulsating type
Auto-Restart time: 30 seconds
Input
Voltage Range180V~285Vac
Maximum Continuous Load900W1350W1800W2340W
Maximum Peak Load1200W1800W2400W3000W
Input Current6 Amp9 Amp12 Amp15 Amp
Input Frequency Range45Hz 70Hz
PhaseSingle
Noise FilteringFull-Time EMI/RFI Filtering
Input EMI Filter150Khz -30Mhz( class A)
Input RFI Filter30Mhz - 1000Mhz( class A)
Over Current ProtectionBy Re-Settable
Over Current Protector
Voltage Range180 V ~ 285 Vac
Power Factor0.98
Audible AlarmOver load alarm: Short-circuit alarm, Thermal alarm
Inrush Surge Capacity<100A, 3mS
Voltage Interruption
Ride Through10mS
Efficiency
Efficiency>89%
Output Connection from Mains
Ground Input and Output Ground Connected
NeutralInput and Output Neutral Connected( after EMC inductor )
Isolation Transformer is not required
Indicators
LCD Control PanelDisplays Input Voltage, Output Voltage, Output Frequency, Temperature, Load Level
Selectable Output Voltage and Output Frequency
LEDN/A
Output Compatibility
Output Compatibility with UPSYes
Environmental and Safety
Operating TemperatureUp to 1500 meters: 0 to 40 (32 to 104)
Transit/Storage Temp-15 to 55 (5 to 131)
Relative Humidity5 – 95% Non-Condensing
Operating Altitude0 3000 Meters
Moisture SensitivityInternal Fan
Audible Noise45 dBA (at 1 meter from surface of unit)
Cooling
Natural VentilationNo
External Cooling Fan ControlForced air cooling by internal fan
Physical
Dimensions W×D×H38×20×18cm
14.96x7.87x7.08in45×20×18cm
17.71x7.87x7.08in51×20×18cm
20.08x7.87x7.08in51×20×18cm
20.08x7.87x7.08in
Weight Net/Gross6.5kg
14.33lbs7.0kg
15.43lbs8.0kg
17.64lbs8.5kg
18.74lbs
Shipping Dimension50.80x33.02x35.56cm
20x13x14in55.88x33.02x35.56cm
22x13x14in63.50x33.02x35.56cm
25x13x14in63.50x33.02x35.56cm
25x13x14in
Shipping Weight7.94 kg
17.50 lbs9.30 kg
20.50 lbs11.57 kg
25.50 lbs11.79 kg
26.00 lbs
Others
Standard AccessoriesInput Power Cords, Type F, Type G, Type I, Type M.
Wall MountableNo
Warranty2 Years, Full Replacement
Quality Control StandardISO9001
Approvals and Safety MarkingsCE